ITEM |
SPECIFICATION |
Capacitance Tolerance
(120Hz 20 ºC ) |
± 20%(M) |
Rated Working
Voltage |
6.3 ~ 160WV |
Operation
Temperature Range |
-40 ~ +85 ºC |
Surge Voltage (V)
( 20 ºC ) |
WV |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
160 |
SV |
8 |
13 |
20 |
32 |
44 |
63 |
79 |
125 |
200 |
|
Leakage Current
( μA)( 20 ºC ) |
I 0.01CV + 3 μA
Whichever is greater after rated voltage applied for 3 minutes
I:Leakage Current ( μA) C:Capacitance( μF) V:Voltage(V) |
Dissipation Factor(%)
(120Hz,20 ºC ) |
WV |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
160 |
DF |
24 |
20 |
16 |
14 |
12 |
10 |
10 |
10 |
20 |
Add 2% per 1000 μF for more than 1000 μF
|
Low Temperature
Characteristics |
Impedance Ratio at 120HZ
Comparison Z \ WV |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
160 |
-25 ºC / 20 ºC |
4 |
3 |
2 |
2 |
2 |
2 |
3 |
2 |
3 |
-40 ºC / 20 ºC |
8 |
6 |
4 |
4 |
4 |
2 |
3 |
3 |
- |
|
Load Life |
After 2000 hours application of W.V.at 85 ºC
The capacitor shall meet the following limits .
(a) Capacitance Change |
Within ± 25% of Initial Measured Value |
(b) Dissipation Factor |
Within ± 200% of Initial Measured Value |
(c) Leakage Current |
Within Initial Measured Value |
|
Shelf Life |
Following characteristics shall be satisfied when return to 25 ºC,
after without rated voltage applied 1000 hours at 85 ºC .
(a) Capacitance Change |
Within ± 25% of Initial Measured Value |
(b) Dissipation Factor |
Within ± 200% of Initial Measured Value |
(c) Leakage Current |
Within Initial Measured Value |
|